Specifications:
Exposure Range (gamma and x-rays):
PEN200mR Scale increments of 10mR
PEN500mR Scale increments of 20mR
PEN2R increments of 100 mR
PEN5R increments of 200mR
PEN20R increments of 1R
PEN2mSv increments of .1mSv
PEN5mSv increments of .2mSv
National Stock Numbers Available
Accuracy:
±10% of true dose for Cs-137 or Co-60 gamma.
Energy Dependence:
±10% maximum change in sensitivity for x and gamma ray energies from
16 keV to 8 MeV.
Rate Response:
Dosimeters are dose rate independent.
Electrical Leakage:
In the absence of radiation, the dosimeters leakage or self discharge is less
than 0.5% of full scale in 24 hours at 50° C. At 20° C dosimeters
will read background radiation. After gross over exposure totaling up to 2000
R the leakage is less than 5% of full scale in 48 hours at 20° C. Thereafter,
the leakage will decrease to original values.
Charging Voltage:
Dosimeters are capable of being charged to "zero" with 140 to 195
volts.
Operational Characteristics:
A maximum change in sensitivity of ±10%
may occur under any probable combination of the following:
A) Temperature range below -20°C (-4°F) or above +50°C (122°F)
B) Greater than 50,000 foot altitude for one month
C) Relative humidity greater than 95%
Highly resistant to shock and vibration.
Weight:
Approx. 19 grams (0.7 oz.)
Size:
PEN- 200, 500
2mSv, 5mSv Length: 11 cm (4.48 inches)
Diameter: 1.5 cm (0.6 inches)
PEN- 2, 5, 20 Length: 11.5 cm (4.52 inches)
Diameter: 1.5 cm (0.6 inches)
Material:
Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic
with metal clip.
Includes:
2 year limited warranty.
Options:
Protective sapphire lens.
![]() |
||||||||||||
| |
|
|
|
|
|
|
|
|
|
|
|
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||||