Compressed air monitoring system for verification of Carbon Monoxide (CO) with electrochemical principle of low maintenance and long life of use, Oxygen (O2) and dew point. It is a complete and portable system ideal to verify the degree of purity and breathable air conditions of virtually any compressor or system:
- Electrochemical sensor for measurement of Carbon Monoxide (CO) in the range of 0-99 ppm
- Electrochemical sensor for oxygen measurement (O2) in the range of 0-25% Vol.
- Dew point from -112 ° F to 68 ° F
- Optional three-stage efficient filtration panel for removal of particulate matter, oil vapors and hydrocarbons from the air line
- LCD display
- Audible and visual alarm set at 5 and 10 ppm CO, 19.5% and 23.5% Oxygen Vol, 4 ° F Dew Point
- Housing in NEMA 4X high strength
- High pressure connection 30 to 145 psi
- NO / NC relays depending on the model
- Operation through 110 VAC or 12 - 24 VDC for up to 24 hours with 2 hour charge cycle